DC Brushless Fans (BLDC)

Photo Mfr. Part # Availability Price Quantity Datasheet Packaging Series ProductStatus Voltage-Rated Size/Dimension Width AirFlow StaticPressure BearingType FanType Features Noise Power(Watts) RPM Termination IngressProtection OperatingTemperature ApprovalAgency
MB6010X12B1-RSR Mechatronics Fan Group DC Brushless Fans (BLDC)

MB6010X12B1-RSR

FAN AXIAL 60X10MM 12VDC TACH

Mechatronics Fan Group
3,591 -

RFQ

FudongIC

Datasheet

Bulk MB6010 Active 12VDC Square - 60mm L x 60mm H 10.20mm 18.7 CFM (0.524m³/min) 0.130 in H2O (32.4 Pa) Ball Tubeaxial Speed Sensor (Tach), Thermal Overload Protector (TOP) 35.0dB(A) - 5300 RPM 3 Wire Leads - - cUL, UL
G8015H12B-RGR Mechatronics Fan Group DC Brushless Fans (BLDC)

G8015H12B-RGR

FAN AXIAL 80X15MM 12VDC

Mechatronics Fan Group
2,575 -

RFQ

FudongIC

Datasheet

Bulk G8015-G Active 12VDC Square - 80mm L x 80mm H 15.30mm 37.0 CFM (1.04m³/min) 0.170 in H2O (42.3 Pa) Ball Tubeaxial Thermal Overload Protector (TOP) 36.0dB(A) - 4000 RPM 2 Wire Leads - - CE, cUL, TUV, UL
F6025X24B1-FSR Mechatronics Fan Group DC Brushless Fans (BLDC)

F6025X24B1-FSR

FAN 24VDC AXIAL 60X60X25 W/TACH

Mechatronics Fan Group
3,592 -

RFQ

FudongIC

Datasheet

Bulk F6025 Active 24VDC Square - 60mm L x 60mm H 25.00mm 27.0 CFM (0.756m³/min) 0.280 in H2O (69.7 Pa) Ball Tubeaxial Auto Restart, Locked Rotor Protection, Speed Sensor (Tach) 41.0dB(A) - 5200 RPM 3 Wire Leads - - CE, cUL, TUV, UL
4556HQ/EG50040S1-C912-S9A Sunon Fans DC Brushless Fans (BLDC)

4556HQ/EG50040S1-C912-S9A

DC BLOWER, 67.5X54X4.6MM, SLEEVE

Sunon Fans
3,146 -

RFQ

FudongIC

Datasheet

Box EG Active 5VDC Rectangular/Rounded - 67.5mm L x 54mm H 4.60mm 2.6 CFM (0.073m³/min) 0.680 in H2O (169.4 Pa) Sleeve Blower Auto Restart, PWM Control, Speed Sensor (Tach) 33.4dB(A) 2 W 5100 RPM 4 Position Rectangular Connector - 14 ~ 158°F (-10 ~ 70°C) CE, CUR, TUV, UL
G5015E12B-RSR Mechatronics Fan Group DC Brushless Fans (BLDC)

G5015E12B-RSR

FAN AXIAL 50X15MM 12VDC

Mechatronics Fan Group
2,290 -

RFQ

FudongIC

Datasheet

Bulk G5015 Active 12VDC Square - 50mm L x 50mm H 15.00mm 16.0 CFM (0.448m³/min) 0.220 in H2O (54.8 Pa) Ball Tubeaxial Thermal Overload Protector (TOP) 34.0dB(A) - 6500 RPM 2 Wire Leads - - CE, cUL, TUV, UL
G5015M05B-RSR Mechatronics Fan Group DC Brushless Fans (BLDC)

G5015M05B-RSR

FAN AXIAL 50X15MM BALL 5VDC WIRE

Mechatronics Fan Group
2,474 -

RFQ

FudongIC

Datasheet

Bulk G5015 Active 5VDC Square - 50mm L x 50mm H 15.00mm 11.0 CFM (0.308m³/min) 0.110 in H2O (27.4 Pa) Ball Tubeaxial Thermal Overload Protector (TOP) 24.0dB(A) - 4500 RPM 2 Wire Leads - - CE, cUL, TUV, UL
MB6010X12B-RSR Mechatronics Fan Group DC Brushless Fans (BLDC)

MB6010X12B-RSR

FAN AXIAL 60X10.2MM 12VDC WIRE

Mechatronics Fan Group
2,006 -

RFQ

FudongIC

Datasheet

Bulk MB6010 Active 12VDC Square - 60mm L x 60mm H 10.20mm 18.7 CFM (0.524m³/min) 0.130 in H2O (32.4 Pa) Ball Tubeaxial Thermal Overload Protector (TOP) 35.0dB(A) - 5300 RPM 2 Wire Leads - - cUL, UL
OD6020-12LB Orion Fans DC Brushless Fans (BLDC)

OD6020-12LB

FAN AXIAL 60X20MM 12VDC WIRE

Orion Fans
2,094 -

RFQ

FudongIC

Datasheet

Bulk OD6020 Active 12VDC Square - 60mm L x 60mm H 20.00mm - - Ball Tubeaxial - - - - 2 Wire Leads - -4 ~ 167°F (-20 ~ 75°C) cURus, TUV
G6015X24B1-RGR-WS Mechatronics Fan Group DC Brushless Fans (BLDC)

G6015X24B1-RGR-WS

FAN AXIAL 60X15.3MM 24VDC WIRE

Mechatronics Fan Group
2,228 -

RFQ

FudongIC

Datasheet

Bulk G6015-G Active 24VDC Square - 60mm L x 60mm H 15.30mm 24.0 CFM (0.672m³/min) 0.290 in H2O (72.2 Pa) Ball Tubeaxial Alarm Sensor, Speed Sensor (Tach), Thermal Overload Protector (TOP) 35.0dB(A) - 5800 RPM 4 Wire Leads - - CE, cUL, TUV, UL
06020SA-12T-EA-00 NMB Technologies Corporation DC Brushless Fans (BLDC)

06020SA-12T-EA-00

TUBEAXIAL 12V FLANGE STD 2 WIRE

NMB Technologies Corporation
2,672 -

RFQ

Box 06020SA Active 12VDC Square - 60mm L x 60mm H 20.00mm 30.4 CFM (0.851m³/min) 0.440 in H2O (109.6 Pa) Ball Tubeaxial Auto Restart 42.5dB 2.88 W 6400 RPM 2 Wire Leads - 14 ~ 158°F (-10 ~ 70°C) -
G4020H24B-RSR-CC Mechatronics Fan Group DC Brushless Fans (BLDC)

G4020H24B-RSR-CC

FAN AXIAL 40X20MM 24VDC WIRE

Mechatronics Fan Group
3,631 -

RFQ

FudongIC

Datasheet

Bulk G4020 Active 24VDC Square - 40mm L x 40mm H 20.00mm 11.0 CFM (0.308m³/min) 0.200 in H2O (49.8 Pa) Ball Tubeaxial Conformal Coating, Thermal Overload Protector (TOP) 29.0dB(A) - 7000 RPM 2 Wire Leads - - CE, cUL, TUV, UL
08015SS-12N-AL-00 NMB Technologies Corporation DC Brushless Fans (BLDC)

08015SS-12N-AL-00

TUBEAXIAL 12V RIB LOCK 3 WIRES

NMB Technologies Corporation
3,239 -

RFQ

Box 08015SS Active 12VDC Square - 80mm L x 80mm H 15.00mm 33.9 CFM (0.949m³/min) 0.140 in H2O (34.9 Pa) Sleeve Tubeaxial Auto Restart, Locked Rotor Sensor 34.0dB 2.52 W 3100 RPM 3 Wire Leads - 14 ~ 158°F (-10 ~ 70°C) -
G8015X24B1-RGR-L40 Mechatronics Fan Group DC Brushless Fans (BLDC)

G8015X24B1-RGR-L40

FAN AXIAL 80X15.3MM 24VDC WIRE

Mechatronics Fan Group
3,598 -

RFQ

FudongIC

Datasheet

Bulk G8015-G Active 24VDC Square - 80mm L x 80mm H 15.30mm 43.0 CFM (1.20m³/min) 0.230 in H2O (57.3 Pa) Ball Tubeaxial Speed Sensor (Tach), Thermal Overload Protector (TOP) 40.0dB(A) - 4800 RPM 3 Wire Leads - - CE, cUL, TUV, UL
G4015H24B-RSR Mechatronics Fan Group DC Brushless Fans (BLDC)

G4015H24B-RSR

FAN 24VDC AXIAL 40X40X15

Mechatronics Fan Group
2,589 -

RFQ

FudongIC

Datasheet

Bulk G4015 Active 24VDC Square - 40mm L x 40mm H 15.00mm 8.0 CFM (0.224m³/min) 0.290 in H2O (72.2 Pa) Ball Tubeaxial Thermal Overload Protector (TOP) 29.0dB(A) - 8000 RPM 2 Wire Leads - - CE, cUL, TUV, UL
PF92251V3-1000U-G99 Sunon Fans DC Brushless Fans (BLDC)

PF92251V3-1000U-G99

FAN AXIAL 92X25MM VAPO 12VDC

Sunon Fans
3,141 -

RFQ

FudongIC

Datasheet

Bulk MagLev® PF Active 12VDC Square - 92mm L x 92mm H 25.00mm 65.0 CFM (1.82m³/min) 0.250 in H2O (62.3 Pa) Vapo-Bearing™ Tubeaxial Auto Restart, Speed Sensor (Tach) 41.6dB(A) 2.76 W 3900 RPM 3 Wire Leads - 14 ~ 158°F (-10 ~ 70°C) CE, CUR, TUV, UL
109P0612H779 Sanyo Denki America Inc. DC Brushless Fans (BLDC)

109P0612H779

FAN 12V 60X15MM W/CONNECTOR

Sanyo Denki America Inc.
2,004 -

RFQ

FudongIC

Datasheet

Box San Ace 60 Active 12VDC Square - 60mm L x 60mm H 15.00mm - - Ball Tubeaxial Locked Rotor Protection 32.0dB(A) - 4100 RPM 2 Position Rectangular Connector - -4 ~ 158°F (-20 ~ 70°C) -
E9225X24B-FSR-L17 Mechatronics Fan Group DC Brushless Fans (BLDC)

E9225X24B-FSR-L17

FAN AXIAL 92X25MM 24VDC WIRE

Mechatronics Fan Group
3,102 -

RFQ

FudongIC

Datasheet

Bulk E9225 Active 24VDC Square - 92mm L x 92mm H 25.00mm 60.0 CFM (1.68m³/min) 0.320 in H2O (79.7 Pa) Ball Tubeaxial Thermal Overload Protector (TOP) 43.0dB(A) - 4000 RPM 2 Wire Leads - - CE, cUL, TUV, UL
FAD1-06025BBMW12-A Qualtek DC Brushless Fans (BLDC)

FAD1-06025BBMW12-A

FAN AXIAL 60X25MM BALL 5VDC WIRE

Qualtek
2,411 -

RFQ

FudongIC

Datasheet

Bulk FAD1-06025-A Active 5VDC Square - 60mm L x 60mm H 25.00mm 17.9 CFM (0.501m³/min) 0.152 in H2O (37.9 Pa) Ball Tubeaxial - 28.1dB(A) 1.75 W 3500 RPM 2 Wire Leads - 14 ~ 158°F (-10 ~ 70°C) CE, cURus, TUV
9A0912G402 Sanyo Denki America Inc. DC Brushless Fans (BLDC)

9A0912G402

FAN 92X25MM 12VDC

Sanyo Denki America Inc.
3,450 -

RFQ

FudongIC

Datasheet

Box San Cooler 92 Active 12VDC Square - 92mm L x 92mm H 25.00mm 62.1 CFM (1.74m³/min) 0.267 in H2O (66.5 Pa) Ball Tubeaxial Locked Rotor Protection 43.0dB(A) 4.68 W 3900 RPM 2 Wire Leads - -4 ~ 140°F (-20 ~ 60°C) CSA, TUV, UL
05125GS-12M-AA-D0 NMB Technologies Corporation DC Brushless Fans (BLDC)

05125GS-12M-AA-D0

BLOWER 12V - STD 2 WIRE

NMB Technologies Corporation
3,888 -

RFQ

Box 0512GS Active 12VDC - - - - - - - - - - - - - -
Total 22657 Records«Prev1... 8586878889909192...1133Next»
Request a Quote
Part Number
Quantity
Contact
Email
Company
Comments
  • FudongIC
    1500+ Daily average RFQ Volume
    FudongIC
    20,000.000 Standard Product Unit
    FudongIC
    1800+ Worldwide Manufacturers
    FudongIC
    15,000+ In-stock Warehouse
    FudongIC

    HOME

    FudongIC

    PRODUCT

    FudongIC

    PHONE

    FudongIC

    USER